Ratedpower-frequencyvoltageU0/U:0.6/1kV.•电缆导体的最高允许长期工作温度(PVC/XLPE):70℃/90℃.siblecontinuousoperatingtemperatureofconductor(PVC/XLPE):70℃/90℃•短路时(最长持续时间。

同轴电缆是专门设计用来传输视频信号的,其频率损失、图像失真、图像衰减的幅度都比较小,能很好的完成传送视频信号的任务。
¬视频信号传输线有同轴电缆(不平衡电缆)、平衡对称电缆(电话电缆)、光缆。
平衡对称电缆和光缆一般用于长距离传输,对于宾馆酒店等建筑一般采用同轴电缆传输视频基带信号的传输方式。
产品在全国几十个煤业集团及矿山上使用,获得了较高的评价和赞誉。
3、使用条件电缆使用环境温度为-40℃~+50;在25℃时湿度为95%;电缆敷设温度≥-10℃;电缆敷设时的弯曲半径MHYV≥10倍电缆外径,其余型号≥15倍电缆外径。
HYA53 / HYAT53 (rat bite/buried) is mainly used to transmit audio, 15 duct | communication cable | (pipe/overhead) HYAC (overhead) HYAT (waterproof) 0 KHZ and analog signals and 2048 kbit/s and under the following digital signal. Under certain conditions, it can also be used to transmit digital signals over 2048kbit/s. Suitable for overhead or pipeline laying in city, suburb and local area, or directly buried. Main product model manufacuring HYA, HYAC, HYAT, HYAT53, HYA531, manufacuring HYA (pipe/overhead) inner conductor wire diameter (mm) : 0.40, 0.50, 0.60, 0.70, 0.80, 0.90, logarithmic (on) : 5-3000-2, HYAC (overhead) inner conductor wire diameter (mm) : Logarithms (right) : 10-300 3, inner conductor diameter (mm) of HYAT (waterproof) : 0.40, 0.50, 0.60, 0.63, 0.70, 0.80, 0.90 (right) : Inner conductor line diameter (mm) : 0.40, 0.50, 0.60, 0.70, 0.80, 0.90 logarithms (yes) : HYA5310 -- 2400 HYAT53 10-600

阻燃电缆电线电缆电缆的燃烧是由于外部加热而产生了易燃气体,要达到阻燃的目的,必须抑制引起燃烧的三要素,即:可燃气体、热量和氧气。
卤化氢气体与空气中的水一旦反应后,即生成“卤化氢酸”,严重腐蚀仪器设备、建筑物造成“二次灾害”。
出厂时各管脚都绞合在一起,或装在金属箔内,使G极与S极呈等电位,防止积累静电荷。
管子不用时,全部引线也应短接。
在测量时应格外小心,并采取相应的防静电感措施。
测量之前,先把人体对地短路后,才能摸触MOSFET的管脚。
**在手腕上接一条导线与大地连通,使人体与大地保持等电位。
再把管脚分开,拆掉导线。
将万用表拨于R×100档,确定栅极。
若某脚与其它脚的电阻都是无穷大,证明此脚就是栅极G。
交换表笔重测量,S-D之间的电阻值应为几百欧至几千欧,其中阻值较小的那一次,黑表笔接的为D极,红表笔接的是S极。
表一:阻燃塑料绝缘控制电缆执行标准:GBGB/T18308.3-2001型号:ZR-KVV额定电压:450/750芯数:2-61标称截面:0.5-6.0电缆可敷设在室内,隧道电缆沟内、桥架、地下、易燃的场合电缆不能承受拉力和压力。
Armoured communication cable armoring cable type: HYA53, HYAT53, HYA23 HYAT23, HYV22, HYA22 (rat, buried) armoring communication cable USES: armoured communication cable mechanical protective layer can be appended to the structure of the cable, with the mechanical strength of the cable, antierosion capability, is vulnerable to mechanical and designed and vulnerable to erosion area telephone cable. Any kind of laying can be adopted, which is more suitable for direct buried laying in rock area. Armored communication cable structure: 1. Basic cable: any filled and unfilled cable with single sheath or double sheath structure. 2. Armored communication cable mechanical protection layer: type 53 adopts 0.15mm thick corrugated steel belt, which is longitudinal wrapped on the basic cable and overlapped on both sides. The surface of the steel belt is coated with plastic to prevent corrosion and water intrusion. The type 23,22 has similar performance with double steel band wrapping. 3. Armored communication cable sheath: black high-molecular weight low-density polyurethane or polyurethane sheath. Sheath thickness may depend on the basic cable outer diameter. 5. The marking contents of armored communication cables include: wire diameter, number of wire pairs, cable model, length, manufacturer name and year of manufacture. 6. Armored communication cable electrical characteristics: the cable meets all the electrical requirements of the basic cable. 6. Cable length: mechanically protected cable is made according to the length of the corresponding basic cable
铠装双绞屏蔽型电缆ASTP-120Ω(forRS485&CAN)onepair18AWG,电缆外径12.3mm左右。
可用于干扰严重、鼠害频繁以及有防雷、防爆要求的场所。
使用时,建议铠装层两端接地,最内层屏蔽一端接地。
JKTRYJ软铜芯交联聚乙烯绝缘架空电缆用于变压器引下线。
JKLYJ/Q交联聚乙烯绝缘轻型架空电缆用于架空电力传输等场所。
JKLGYJJKLGYJ/Q钢芯铝绞线交联聚乙烯绝缘架空电缆用于架空电力传输等场所,并能承受相当的拉力。

LJLGJ铝绞线及钢芯铝绞线用于架空固定敷设。
-=特种电缆=-ZR-X阻燃电缆敷设在对阻燃有要求的场所,GZR电缆敷设在阻燃要求特别高的场所。
GZR-X隔氧层阻燃电缆WDZR-X低烟无卤阻燃电缆敷设在对低烟无卤和阻燃有要求的场所,GWDZR电缆敷设在要求低烟无卤阻燃性能特别高的场所。
MHJYV(PUJYV)聚乙烯绝缘阻燃聚氯乙烯护套加强矿用通讯电缆2-57/0.28(三钢四铜)用于平巷、斜巷、有较好的抗拉强度。
MHYVP煤矿用聚乙烯绝缘编织屏蔽聚氯乙烯护套通信电缆(5-10)*2*(0.75-1.5)用于电场干扰较大的场所作信号传输,适用于固定敷设。
51系列单片机有5个中断源,其中有2个是外部输入中断源INT0和INT1。
可由中断控制寄存器TCON的IT1(TCON.2)和IT0(TCON.1)分别控制外部输入中断1和中断0的中断触发方式。
若为0,则外部输入中断控制为电平触发方式;若为1,则控制为边沿触发方式。
这里是下降沿触发中断。
问题的引出几乎国内所有的单片机资料对单片机边沿触发中断的响应时刻方面的定义都是不明确的或者是错误的。
文献中关于边沿触发中断响应时刻的描述为“对于脉冲触发方式(即边沿触发方式)要检测两次电平,若前一次为高电平,后一次为低电平,则表示检测到了负跳变的有效中断请求信号”,但实际情况却并非如此。
JYPV-3铜芯聚乙烯绝缘聚氯乙烯护套铜丝编织总屏蔽电子计算机电缆。
JYP2V-1铜芯聚乙烯绝缘聚氯乙烯护套铜/塑复合膜分屏蔽电子计算机电缆。
JYP2V-2铜芯聚乙烯绝缘聚氯乙烯护套铜/塑复合膜分屏蔽及总屏蔽电子计算机电缆。

绝缘电阻:>200M欧姆×KM。
使用温度:-30~+70℃。
弯曲半径:15×电缆外径。
阻燃特性:IEC60332.1。
参考标准:GB5023、IEC60227、HDVDE21.5S3。
包装规格:100m、500m、1000m。
电缆的阻燃性能符合国家标准GB 12666.5的要求。
耐火BV线在导体和绝缘层之间有一层耐火云母带,耐火BV线在着火的时候仍然可以正常使用一段时间啊,电缆缆的耐火性符合国家标准GB 12666.6的要求。
用途:耐火电缆广泛应用于高层建筑、地下铁道、地下街、大型电站及重要的工矿企业等与防火安全和消防救生有关的地方,例如,消防设备及紧急向导灯等应急设施的供电线路和控制线路。
2.电缆敷设安装允许弯曲半径非铠装电缆应不小于电缆外径的10倍;铠装电缆应不小于电缆外径的15倍。