IXEF PARA 1022/9008 索尔维

IXEF PARA 1022/9008 索尔维

发布商家
东莞市晶宏塑胶原料有限公司
联系人
蒋珂(先生)
职位
经理
电话
18200646066
手机
18200646066
特性
耐化学 良好的消毒性 超高刚性
型号
1022/9008
用途
家具 • 高光应用 • 医疗器械

IXEF PARA 1022/9008 索尔维-->PARA-GF50< 阻燃等级: HB 缺口冲击: 11.22 kJ/m² 符合规定: UL材料特性: 良好的外观 • 超高刚性 • 耐化学性 • 抗蠕变 • 通用级 • 尺寸稳定 • 良好的消毒性 • 高流动性 • 高强度 • 低吸水率


材料用途: 手机 • 电器用具 • 汽车领域的应用 • 汽车内部零件 • 电气元件 • 家具 • 高光应用 • 医疗器械 • 体育用品应用 • 外科器械汽车规格: ASTM D6779 PA111G50 • BOSCH N28 BN05-OX1 Color:0008 Natural • BOSCH N28 BN05-OX1 Color:9008 Black • GM GM7001M PAMXD6(A4,A22,A64,BA651,G30,MS1700,NS335)Color:9008 Black • GM GM7001M PAMXD6(A4,A22,A64,BA751,G30,MS1700,NS350)Color:0008 Natural



注射说明

Hot runners: 250°C to 260°C (482°C to 500°F)StorageIxef® compounds are shipped in moisture-resistant packages at moisture levels according to specifications. Sealed, undamaged bags should be preferably stored in a dry room at a maximum temperature of 50°C (122°F) and should be protected from possible damage. If only a portion of a package is used, the remaining material should be transferred into a sealable container. It is recommended that Ixef® resins be dried prior to molding following the recommendations found in this datasheet and/or in the Ixef® processing guide.DryingThe material as supplied is ready for molding without drying. However, If the bags have been open for longer than 24 hours, the material needs to be dried. When using a desiccant air dryer with dew point of -28°C (-18°F) or lower, these guidelines can be followed: 0.5-1.5 hour at 120°C (248°F), 1-3 hours at 100°C (212°F), or 1-7 hours at 80°C (176°F).Injection MoldingIxef 1022 compound can be readily injection molded in most screw injection molding machines. A general purpose screw is recommended, with minimum back pressure.The measured melt temperature should be about 280°C (536°F), and the barrel temperatures should be around 250 to 260°C (482 to 500°F) in the rear zone, gradually increasing to 260 to 290°C (500 to 554°F) in the front zone. If hot runners are used, they should be set to 250 to 260°C (482 to 500°F).To maximize crystallinity, the temperature of the mold cavity surface must be held between 120 and 140°C (248 and 284°F). Molding at lower temperatures will produce articles that may warp, have poor surface appearance, and have a greater tendency to creep. Set injection pressure to give rapid injection. Adjust holding pressure and hold time to maximize part weight. Transfer from injection to hold pressure at the screw position just before the part is completely filled (95-99%).


人气
79
发布时间
2023-11-24 00:48
所属行业
其他工程塑料
编号
40240957
我公司的其他供应信息
相关ixef产品
拨打电话
QQ咨询
请卖家联系我