在交联聚乙烯绝缘高阻燃的基础上又开发了低烟无卤高阻燃隔氧层动力电缆,其低烟无卤性能符合国家标准GB/T17651.1.2和GB/T17650.1.2。
这样本公司的交联聚乙烯动力电缆的整体水平低于国内领先地位。

。
ZR-KVVRP 聚氯乙烯绝缘和护套阻燃铜丝屏蔽控制软电缆。
KVVRP22 聚氯乙烯绝缘和护套编织屏蔽铠装控制软电缆。
ZR-KVVRP22 聚氯乙烯绝缘和护套编织屏蔽铠装阻燃控制软电缆。
主要用于火灾报警、消防设备、排烟设备、以及紧急通道运输、照明等应急设施的供电线路中需要耐火的场合。
(4)电缆安装时的最小弯曲半径:a、低烟无卤阻燃、耐火控制电缆:无铠装层的电缆应不小于电缆外径的6倍,有铠装或铜带屏蔽结构的电缆应不小于电缆外径的12倍。
HYA53 / HYAT53 (rat bite/buried) is mainly used to transmit audio, 15 duct | communication cable | (pipe/overhead) HYAC (overhead) HYAT (waterproof) 0 KHZ and analog signals and 2048 kbit/s and under the following digital signal. Under certain conditions, it can also be used to transmit digital signals over 2048kbit/s. Suitable for overhead or pipeline laying in city, suburb and local area, or directly buried. Main product model manufacuring HYA, HYAC, HYAT, HYAT53, HYA531, manufacuring HYA (pipe/overhead) inner conductor wire diameter (mm) : 0.40, 0.50, 0.60, 0.70, 0.80, 0.90, logarithmic (on) : 5-3000-2, HYAC (overhead) inner conductor wire diameter (mm) : Logarithms (right) : 10-300 3, inner conductor diameter (mm) of HYAT (waterproof) : 0.40, 0.50, 0.60, 0.63, 0.70, 0.80, 0.90 (right) : Inner conductor line diameter (mm) : 0.40, 0.50, 0.60, 0.70, 0.80, 0.90 logarithms (yes) : HYA5310 -- 2400 HYAT53 10-600

矿用电缆的成本价格计算平方X1.83=铜的重量X当时的铜价+铠装的价格(重量X0.4元/斤)=成本价格+10%的加工费电缆的价格=制造材料成本+固定费用+税收+业务费+利润制造材料成本=材料成本*(1+材料消耗)(材料成本即为理论计算出来的值)固定费用根据各个公司的情况有所不同,一般包括生产工资、管。
10.退出子程序。
应用实例实例应用2在首次扫描时,调用SBR0,在首次扫描,配置HSC1:SMB48=16#F8意思就是使能计数器、写初始值、写预置值、设初始方向为增计数、选择启动和复位输入高电平有效、选择4倍速模式、配置HSC1为带启动和复位输入的正交模式、SMD48=0表示清除HSC1的初始值。
置HSC1的预置值为50。
当HSC1的当前值=预置值时,执行INT_0。
全局中断允许。
执行HSC1,执行HSC1,清除HSC1的初始值、选择写入新的初始值和HSC1使能。
电缆导体的长期允许工作温度-40~+50℃; 月平均最大相对湿度为≤95%(+25℃时) 电缆允许附设与安装的温度应不大于-10℃ 电缆最小弯曲半径:MHYV、MHJYV型电缆为电缆外径的10倍,其它型号的电缆为外径的15倍。
MHYV(PUYV)(1×21×42×23×24×25×26×28×210×2)1/1.0、1/1.38聚乙烯绝缘聚氯乙烯护套煤矿用信号电缆用于矿场作普通信号传输,适用于固定敷设。
MHYVRP7/0.30、7/0.37、7/0.43、7/0.52(1~10对、1×4)聚乙烯绝缘铜丝编织屏蔽聚氯乙烯护套煤矿用信号电缆,用于电场干扰较大的场所作信号传输,电缆较柔软。
Product introduction - plastic insulated control cable | | KVV control cable KVVR control cable | | KVVP control cable shielding control cable KVVP | | KVVRP shielding control cable KVVP2 control cable | | KVVP2-22 control cable KVV22 sheathed control cable | control cable KVV | control cable KVVR | control cable KVVP | control cable KVVRP | control cable KVV22 product details: plastic insulated control cable: GB9330-88 scope of application: This product is fit for ac rated voltage up to and including 450/750 control, monitoring circuit and protection circuit using features: 1, the conductor long-term allowed working temperature is 70 ℃. 2, when laying temperature 0 ℃ or higher. 3. Small bending radius: 4. For unarmored cable, it should be no less than 6 times the outer diameter of the cable. 5. The cable with armor or copper shield shall not be less than 12 times the outer diameter of the cable. 6. The soft cable with screen shielding structure shall not be less than 6 times the outer diameter of the cable. 7. Model and name: KVV copper core PVC insulated PVC sheath control cable
为了提高电缆的质量,我们选择高电性能绝缘材料生产,例如1.8/3千伏变频电机专用电缆,采用10千伏交联绝缘材料,6/10千伏变频电机专用电缆采用35千伏交联绝缘材料,导体屏蔽、绝缘屏蔽和绝缘材料均采用了进口材料。

NH-VV33NH-VLV32聚氯乙烯绝缘细圆钢丝铠装聚乙烯护套耐火电力电缆PVCinsulatedthinsteel-wirearmouredPEsheathpowercableNH-VV42NH-VLV42聚氯乙烯绝缘粗钢丝铠装聚氯乙烯护套电力电缆PVCinsulatedthinste。
铁路用塑料绝缘和护套信号电缆详细说明 :1、产品执行标准:TB,Q3210HL,GB/T。
2、用途:本产品适用于传输控制信号及音频信号传输,特别广泛应用于电路自动系统。
综合扭绞聚乙烯绝缘及塑料护套信号电缆PZYV电缆芯数(芯):4、6、8、9、12、14、16、19、21、24、28、30、33、37、42、44、48、52、56、61。
YKM:星型启动时吸合,切换三角形时不吸合middot;KM:星型启动时不吸合,切换三角形时吸合我们要记住星三角起动过程:1.按下起动按钮2.主KM和YKM接触器吸合,星型起动3.经过时间继电器延时4.切断YKM,并接通△KM,切换到三角型.通电延时型时间继电器:通电后,在设定的时间后才动作,和接触器一样,有线圈,常开触点,常闭触点,但这种通电延时型,不是立刻动作,而是在你设定的时间后才动作。
:设定3秒,线圈通电后,常开常闭触点不会立刻动作,要3秒钟时间到了才动作。
(SYV线、RVVP线、RVSP线、RVV线、AVVR线、BV线、BVR线、RV线、RVS线、RVB线、RVVB线)SYV实芯聚乙烯绝缘聚氯乙烯护套射频同轴电缆 :用于视频监控线路、会议视频等电子线路架设、工程装修讯号传输、影音器材连接以及其它电子装置,无线电通讯广播设备的有关无线电电子设备中传输射。

型号名称MVV煤矿用聚氯乙烯绝缘聚氯乙烯护套电力电缆MVV22煤矿用聚氯乙烯绝缘钢带铠装聚氯乙烯护套电力电缆MVV32煤矿用聚氯乙烯绝缘细钢丝铠装聚氯乙烯护套电力电缆MV42煤矿用聚氯乙烯绝缘粗钢丝铠装聚氯乙烯护套电力电缆概述:耐火电缆是指在火焰燃烧情况下能够保持一定时间安全运行的电缆。
4、型号、名称和使用范围型号名称使用范围铜芯铝芯VVVLV聚氯乙烯绝缘聚氯乙烯护套电力电缆敷设在室内、管道内、隧道内VYVLY聚氯乙烯绝缘聚乙烯护套电力电缆敷设在室内、管道内、管道中VV22VLV22聚氯乙烯绝缘钢带铠装聚氯乙烯护套电力电缆敷设在地下,能承受机械外力作用V。
Sheathed control cable products use feature: the cable conductor of long term working temperature should be allowed no more than 70 ℃. When the cable temperature under installation should not below 0 ℃, when laying bending radius should not less than 10 times of cable diameter. The cable with armor layer or copper band shielding structure shall not be less than 12 times the outer diameter of the cable.