电缆导体长期工作温度应不超过70℃。
普通护套的电缆在环境温度不低于-5℃下敷设,耐塞护套为-10℃。
弯曲半径不低于电缆外径的15倍(敷设时),且适用于任何水平差的干扰。
天津市电缆总厂第一分厂专业生产研发的市内通信电缆,电话电缆,大对数通信电缆,计算机电缆,通信设备电源线;铁路信号电缆,各种**性证书齐全,质量可靠。

Integrated stranded railway cable GB/ t2476-1993. Railway cables are suitable for transmission under rated voltage ac 500V or dc 1000V and below. Product name, model, specification and scope: plastic insulation and polyurethane sheath railway cable PTYAH; PTYA; PZYA; PTYV; PTYY,; PTY22; PTY23; (PZY02; PZY03; PZY23 PZY22) 1/0.8mm (1/1.0mm) 2-48 core is suitable for railway communication, fire alarm, telegraph and other automatic devices with rated voltage ac 500V or dc 1000V or below.
4、电缆安装敷设温度应不低于-20℃。
2、电缆导体长期允许工作温度为:氟塑料外护层为200℃,聚氯乙烯外护层为105℃,硅橡皮外护层为180℃。
3、电缆的敷设温度应不低于:聚氯乙烯护套电缆0℃,硅橡皮护套电缆-20℃,氟塑料护套电缆-20℃。
U0--任一绝缘导体和"地"(电缆的金属护层或周围介质)之间的电压有效值。
U--多芯电缆或单芯电缆系统任何两相导体之间的电压有效值,当用于交流系统时,电缆的额定电压应至少等于所使用电缆系统的标称电压。
该条件均适用于U0和U值。

注意:电线电缆安装应熟悉电线电缆性能的安装人员或专职技术人员担任,如仍有不清事项,请向相关技术部门或我厂技术部咨询。
射频电缆适用于无线电通讯和采用类似技术的电子装置中使用的实心聚乙烯绝缘射频电缆。
。
4.工作电容:平均值52±2nF/km5.远端串音防卫度:150kHZ时指定组合的功率平均值大于69dB/km。
我要说的是,变频器的效率可能比想象中的要高,现在主流变频器的技术通常能达到0.9以上,电机降低速度时,效率是下降了,但能耗是按照转速的三次方比例下降的。
可以说,考虑变频器和电机的效率时,变频器技术依旧是节能的。
当然,前提是存在降低负荷运行的前提。
至于整体经济划不划算,只能针对具体项目进行技术经济比较了。
思考:变频器节能技术是比较成熟的技术,否所有负载、所有运行工况都适合配置变频器,是否定的。
石油膏电缆HYAT、ZR-HYAT22、ZRC-HYAT23、ZR-HYAT53石油膏电缆HYAT、HYAT22、HYAT23、ZRC-HYAT53石油膏电缆HYAT、HYAT22、HYAT23、HYAT53石油膏电缆HYAT、HYAT22、HYAT23、HYAT53石油膏电缆HYAT、HYAT22。
在电缆燃烧时会释放大量的浓烟和卤酸气体,卤酸气体对周围的电气设备有腐蚀性危害需要带上防毒面具才能接近现场进行灭火。
电缆燃烧时给周围电气设备以及救援人员造成危害,不利于灭火救援工作,从而导致严重的“二次危害”。
其实AWG(AmericanWireGauge)是美制电线标准的简称,AWG值是导线厚度(以英寸计)的函数。
下表是AWG与公制、英制单位的对照表。
其中,4/0表示0000,3/0表示000,2/0表示00,1/0表示0。

DJVVP2-2212×2×0.5(.5)铝塑复合膜分对屏蔽铠装(DJVVP2,计算机用屏蔽电缆,计算机屏蔽电缆)。
产品名称:KVVRP2-22--ZR-KVVRP2-22--ZR-KVVP2-22-R铜芯绝缘和护套铜带屏蔽钢带铠装(阻燃)控制电缆。
产品在全国几十个煤业集团及矿山上使用,获得了较高的评价和赞誉。
3、使用条件电缆使用环境温度为-40℃~+50;在25℃时湿度为95%;电缆敷设温度≥-10℃;电缆敷设时的弯曲半径MHYV≥10倍电缆外径,其余型号≥15倍电缆外径。
PVV铜芯聚氯乙烯绝缘聚氯乙烯护套信号电缆。
PVV32钢芯聚氯乙烯绝缘镀锌钢丝带铠装聚氯乙烯护套信号电缆。
PYV钢芯聚乙烯绝缘聚氯乙烯护套、信号电缆。
PYV32钢芯聚乙烯绝缘钢带铠装聚氯乙烯护套信号电缆。
交流接触器选用有7个原则,如下:选择接触器的极数。
选择主电路的参数,包括额定工作电压,额定工作电流,额定通断能力和耐受过载能力等。
选择合适的控制电路参数。
选择合适的电寿命和使用类别。
对于电动机用接触器,要根据电动机运行的情况来分别考虑。
对于单向运行的电动机,风机、水泵类负载,可按AC-3类别来选用交流接触器;对于可逆的电动机,其反向运转、点动和反接制动时接通电流可达8倍额定电流以上,要按AC-4类别来选用交流接触器。
型号Type名称铜芯铝芯VV-PYJV-PVLV-PYJLV-P聚氯乙烯(交联聚乙烯)绝缘金属屏蔽聚氯乙烯护套电力电缆VV22-PYJV22-PVLV22-PYJLV22-P聚氯乙烯(交联聚乙烯)绝缘金属屏蔽钢带铠装聚氯乙烯护套电力电缆VV32-PYJV32-PVLV32-PYJLV。
Fire control cable USES: this product has high fire-resistant ability, can withstand direct flame combustion and in a certain period of time not short circuit or open circuit fault occur, when the fire broke out, to put out the fire and reduce the loss. It is suitable for electric devices and control systems in places with high fire risk and fire control importance. Product standard: Q/ 320831nhn004-1996 25 ℃ ~ + 105 ℃ and 60 ℃ ~ + 200 ℃. Two kinds of refractory characteristics: comply with GB12666.6-90: A class: the flame temperature of 950 ℃ to 1000 ℃ class B: flame temperature 750 ℃ to 800 ℃ the burning time of 90 min burning time: 90 min additional voltage 500 v 3 additional voltage 500 v 3 A current a. flame retardant properties: Comply with class A of gb12666.5-90 test • minimum allowable bending radius of cable: The armoured not less than 12 times the cable diameter models: main material PVC insulated PVC sheathed low smoke low halogen low smoke zero halogen sheath insulation fluorine plastic insulation Low smoke low halogen sheath fluorine plastic insulation Low smoke zero halogen sheath fluorine plastic insulation fluorine plastic sheath Single strand conductors without shielding NH - KVV NH - KV D Y D NH - KFV DNH KFY D NH - KFF single strands of copper conductor shielding NH - KVVP NH - KV D Y D P NH - KFV D P NH - KFY D P NH - KFFP single stranded conductor copper tape screened NH - KVVP 2 NH - KV D Y D P 2 NH - KFV D P 2 NH - KFY D P 2 NH - KFFP 2 soft conductor shielding NH - no KVVR NH - KV D Y D R NH - KFV NH - KFY D D R R NH - KFFR soft copper conductor shielding NH - KVVRPNH - KV D Y D RP NH - RP NH - KFY KFV D D RP NH - KFFRP no shielding NH - steel tape armoured KVV NH - 22 KV D Y D - 22 NH - KFV NH - KFY D - D - 22 of 22 NH - KFF 22 note: PVC insulation structure by using the 105 ℃ resistance fuel used for refractory compound insulation structure. Specifications: Section 0.5 0.75 1.0 1.5 2.5 4 June 15 mm 2 above and below 2.5 mm 2 class A 1/0.80 1/1.13 1/1.13 1/1.38 1/1.38 1/1.13 1/1.13 PVC fluorine plastic sheath PVC fluorine plastic sheath class B 19/0.1 19/0.2 19/0.2 19/0.3 19/0.3 19/0.2 19/0.2 4-2-2-61 core 37 core 27 Core 4-14 core technical indicators: Performance can project technical indicators conductor dc resistance (20 ℃) or less Ω/km nominal section 0.5 0.75 1.0 1.5 2.5 4 6 class A 36.0 24.5 18.1 12.1 7.41 4.61 3.08 39.0 26.0 26.0 13.3 7.98 4.95 19.5 B test voltage 3000 V / 5 min not breakdown insulation resistance M Ω 1000 km or more refractory characteristics through the class A, Class B (according to gb12666.5-90 test) passed class A (according to gb12666.5-90 test).

●三相系统用电缆的Uo值推荐如下表:UkvUmkvUo*kvA和B类系统C类系统67.23.66101268.71517.58.71220241218303618-3540.52126A类系统--该类系统任何一相导体与地或接地导体接触时,能在1min内与。
在四线组外扎一标识扎带,扎带颜色:红、绿、白。
填充材料填充式电缆应在缆芯的间隙及缆芯与包带的间隙均匀而连续地填满符合规定的填充复合物。
缆芯包带缆芯包带用具有足够的隔热性能和机械强度的绝缘带重叠绕包。
以防导体绝缘在加屏幕和挤出挤套过程中粘接、变形和损伤。