JK-SMD0603L系列自复保险丝
Electrical characteristics(25℃)
Part number | V max (V dc) | Imax (A) | I hold | I trip | Pd typ (W) | Time to trip | R@25℃ | ||
@25℃ | @25℃ | Current | Time | R min | R1max | ||||
(A) | (A) | (A) | (Sec) | (W) | (W) | ||||
JK-SMD-0603-035L | 6.0 | 50.0 | 0.35 | 0.70 | 0.5 | 8.0 | 0.1 | 0.15 | 1.0 |
JK-SMD-0603-050L | 0.5 | 1.0 | 0.6 | 0.07 | 0.4 | ||||
JK-SMD-0603-075L | 0.75 | 1.5 | 1.0 | 0.055 | 0.25 | ||||
JK-SMD-0603-100L | 2.0 | 2.0 | 0.045 | 0.22 | |||||
JK-SMD-0603-125L | 1.25 | 2.5 | 3.0 | 0.035 | 0.18 | ||||
JK-SMD-0603-150L | 3.0 | 4.0 | 0.025 | 0.12 | |||||
JK-SMD-0603-175L | 1.75 | 3.5 | 5.0 | 0.015 | 0.07 | ||||
JK-SMD-0603-200L | 4.0 | 0.012 | 0.065 | ||||||
JK-SMD-0603-260L | 2.6 | 5.2 | 0.008 | 0.055 | |||||
JK-SMD-0603-300L | 6.0 | 0.05 |
IH=Hold current: maximum current at which the device will not trip at 25℃ still air.
IT=Trip current: minimum current at which the device will always at 25℃ still air.
V max=Maximum voltage device can withstand without damage at rated current.
Imax=Maximum fault current device can withstand without damage at rated voltage.
T trip=Maximum time to trip(s) at assigned current.
Pd=Typical power dissipation: typical amount of power dissipated by the decice when in state air environment.
R min=Minimum device resistance at 25℃ prior to tripping.
R max=Maximum device resistance at 25℃ prior to tripping.