Power frequency withstand voltage test: the power cable should undergo no breakdown at 3500V and 5min. Control cables shall withstand 3000V and shall not be punctured for 5min. Should be subjected to 15 ℃ low temperature winding test and low temperature impact test. After the test sample surface should be no perception of visible cracks.

执行标准GBQ/WTL使用特性1.电缆额定电压UO/U:450/750V,交流聚烯烃UO/U为0.6/1KV2.电缆长期工作温度为:-20℃-90℃,-40℃-105℃3.推荐弯曲半径:无铠装电缆应不小于电缆外径的6倍,有铠装或铜带屏蔽结构的电缆应不小于电缆外径的12倍。
Power frequency withstand voltage test: the power cable should undergo no breakdown at 3500V and 5min. Control cables shall withstand 3000V and shall not be punctured for 5min. Should be subjected to 15 ℃ low temperature winding test and low temperature impact test. After the test sample surface should be no perception of visible cracks.
EISC-SS阻燃本质安全电缆EISC-SS-R阻燃电缆(电线)(企业标准)本企业标准主要技术指标系参照IEC出版物及英国BS5308Part1标准资料编制。
用途:本产品识用于交流额定电压450/750V及以下,抗射频干扰及抗近场耦合能力较强的对本质安全要求的敷设场所;也适用于有瓦斯爆炸环境运作的工业部门的集散系统和本质安全电路信号传输等。

6.超过500Kbit/s的数据传输速率时应避免使用短截线段,应使用市场上现有的插头可使数据输入和输出电缆直接与插头连接,总线插头可在任何时候接通或断开而并不中断其它站的数据通信。
“天联”牌2芯紫色电缆6XV1 830 0EH10多次被消费者协会评为优质产品。
在RS-485无协议通信方法控制变频器中,PLC是通过RS串行通信指令进行编程控制。
系统构成系统的硬件组成为:FX2N系列PLC(产品版本V3.00以上)1台;FX2N-485-BD通信板1块(最长通信距离50m)或FXON-485ADP1块+FX2N-CNV-BD板1块(最长通信距离500m);带RS-485接口的三菱变频器(F700系列、S500系列、E500系列、F500系列、A500系列)等,可以互相混用,但总数量不超过8台。
信号电缆分为:铁路信号电缆,PVC绝缘信号电缆,控制信号电缆,矿用信号电缆信号电缆分为:铁路信号电缆,PVC绝缘信号电缆,控制信号电缆,矿用信号电缆铁路信号电缆用途:适用于额定电压交流500V或直流1000V及以下传输铁路信号、音频信号或自动信号装置的控制电路,其中综合护套、铝护套铁路信号电缆具有一。
Our company guarantees that the products provided by us can operate reliably and reliably under normal installation, normal operation and conditions.
铁路信号电缆使用特性:(1)电缆的使用环境温度为-40℃~+60℃(2)电缆导体长期工作温度应不超过+70℃。
(3)电缆敷设环境温度:聚氯乙烯外护套电缆应不低于0℃;聚乙烯外护套电缆应不低于-20℃。
(4)电缆的允许弯曲半径:非铠装电缆应不小于电缆外径的10倍;铠装电缆应不小于电缆外径的15倍。

接地引出线要求采用我镀锡编织铜线,和电缆铜带连接时应用铬铁锡焊,不宜用喷灯封焊,以免烧损绝缘。
③三相铜带屏蔽应分别与地线相连,注意屏蔽接地线和钢铠接地线应分别引出,相互绝缘,焊接地线的位置应尽量靠下。
对电缆端头和中间接头的基本要求:a.导体连接好;b.绝缘可靠,推荐采用辐照交联热收缩型硅橡胶绝缘材料;c.密封良好;d.足够的机械强度,能适应各种运行条件。
IA-DJVVP3R IA-DJYVP3R IA-DJYJVP3R 本安型、铝塑复合膜总屏蔽软结构 。
IA-DJVPVPR IA-DJYPVPR IA-DJYJPVPR 本安型、编织分对屏蔽、总屏蔽(铜丝或镀锡丝)软结构。
Model specification of frequency conversion cable: series code BP frequency conversion cable; Insulation code YJ crosslinked polyethylene insulation; V polyvinyl chloride sheath; E halogen-free low smoke polyolefin sheath; Shielding code P copper wire braided shielding; P1 copper wire wound shielding; P2 copper band shielding; P3 aluminum strip shielding; TP2 concentric conductor + copper band shielding structure; P1-2 double shielding of copper wire winding + copper tape wrapping; PX12 copper band shielding + tin coated copper wire braided double shielding; Armor code 22 steel belt armor; 32 steel wire armouring; Flame retardant code ZR common flame retardant type; WDZ low smoke halogen-free flame retardant type.
不少早期的辅助设计软件没有离线仿真功能,那就只能下载到PLC之后,再进行调试。
软件下载从软件设计用的个人计算机将完成的指令集下载到PLC中,可以在生产厂家提供的手册指导下进行,一般不会遇到什么困难。
只要选用正确的通信电缆,接到正确的端口,正确设定通信参数即可。
注意事项如下。
须设置软件密码,以保护知识产权。
不要随意设置,一定要事先做好记录,再输入1该密码。
否则可能会带来麻烦。
记下该软件的版本号。
一般,控制软件需要经过多次调试才能完成,其中可能需要反复修改。
4.成缆时把四根线芯排列为红,绿,蓝,白,排流线,排流线要和线芯一起绞合,千万不要纵放,成缆时不要加填充物,缆芯外用铝箔绕包,而后再绕包一层聚酯膜,在外有一层铜丝编织屏蔽(屏蔽铜丝不镀锡)。
5.护套:护前直径是8.2毫米,护后直径12毫米(11.7--12毫米之间),护套为阻燃蓝色护套。
MHYVP:聚乙烯绝缘聚氯乙烯护套煤矿用信号电缆,用于电场干扰较大的场所作信号传输,可用于固定敷设阻燃变频电缆产品用途阻燃变频电缆主要用于变频电源和变频电机之间,连接用的电缆,以及额定电压1KV及以下的,输配电线路中,作输送电能用.尤其适用于造纸、冶金、金属加工、矿山、铁路和食品加工等行业。

ZR-BPVVP聚氯乙烯绝缘和护套铜丝编织屏蔽变频电力电缆。
ZR-BPVVP2聚氯乙烯绝缘和护套铜带绕包屏蔽变频电力电缆。
ZR-BPVVPP2聚氯乙烯绝缘和护套铜丝编织铜带绕包屏蔽变频电力电缆。
ZR-BPVVP3聚氯乙烯绝缘和护套铝聚酯复合膜绕包屏蔽变频电力电缆。
适合任何弱电安防工程使用。
由于在芯线的外面包有一层铜丝屏蔽层,适合于在一些干扰比较大的地方使用,亦可用于对传输的信号要求严格的场合。
主要用于各种家用电器、仪器仪表、监控等设备的内部连接、控制信号的传递。